Himed study shows importance of post processing in 3D printed titanium implants

Apatitic abrasive blasting via proprietary MATRIX MCD shown to increase bone-to-implant contact, encouraging tissue growth

Stay up to date with everything that is happening in the wonderful world of AM via our LinkedIn community.

For 3D printed titanium and titanium alloy medical implants, surface optimization is not simply an enhancement but an absolute necessity. Himed, a specialist in bioceramic coatings and 3D printable bioceramic materials (the company is also a partner of Lithoz on bioceramics 3D printing), has shown that a carefully engineered surface topography is critical for successful osseointegration, allowing new bone to firmly anchor to the implant. In particular, the company highlights apatitic abrasive blasting via its proprietary MATRIX MCD technique as the pinnacle of post-processing excellence for orthopedic titanium implants.

Scientific studies have confirmed that an optimized surface texture improves bone adhesion and promotes stronger tissue integration. Post-processing is essential for eliminating surface irregularities and enhancing biocompatibility, whether produced through subtractive machining or additive manufacturing.

In the case of 3D printed implants, post-processing plays a crucial role in removing residual titanium beads—microscopic byproducts of the additive process. If left unaddressed, these particulates pose a significant risk, potentially detaching during sterilization, packaging, or even after implantation, which could lead to serious complications.

Enhance the success of 3D printed medical implants with surface optimization. Discover the benefits of apatitic abrasive blasting via MATRIX MCD  for improved osseointegration.
Increasing SEM magnifications of an additive manufactured Ti64 spinal spacer demonstrates that a diversity of scale exists among the residual beads. All images are the property of Himed, LLC.

Residual beads in 3D printed titanium implants

High-resolution imaging, particularly scanning electron microscopy (SEM), reveals that titanium beads frequently remain embedded in the intricate surfaces and cavities of 3D printed Ti64 spinal spacers. These residual particulates require precise removal to prevent potential clinical risks. Additionally, contact points with the build platform contribute to surface irregularities, making refinishing essential to ensure a smooth and consistent texture.

While titanium is inherently biocompatible, the long-term physiological effects of detached titanium debris remain uncertain. To maintain both the structural and biological integrity of medical implants, post-processing must effectively eliminate these residual particles while preventing the introduction of new contaminants. Among the various post-processing techniques, only one method consistently achieves complete purification without compromising the titanium substrate.

Common post-processing techniques

Aluminum Oxide (Al₂O₃) Abrasive Blasting is based on aluminum oxide (alumina), which ranks at 9 on the Mohs hardness scale and is a widely used abrasive due to its exceptional hardness. It effectively removes residual titanium beads, refining the implant’s surface. However, because of its brittle nature, aluminum oxide fragments, upon impact, embed tiny particulates into the softer titanium surface. These inclusions are highly problematic, as they remain trapped within the metal even after acid treatments, making complete removal nearly impossible.

Enhance the success of 3D printed medical implants with surface optimization. Discover the benefits of apatitic abrasive blasting via MATRIX MCD  for improved osseointegration.
SEM imagery of a 3d-printed Ti64 spinal spacer following abrasive blasting with aluminum oxide grit. Note the dark colored areas across the surface—these are representative of abrasive material embedded in the Ti surface during application. All images are the property of Himed, LLC.

Studies have demonstrated that aluminum oxide contamination alters the implant’s elemental composition, with embedded particulates potentially dislodging after implantation and raising biocompatibility concerns. SEM imaging confirms the presence of aluminum oxide particles deeply embedded in the titanium surface. At the same time, energy-dispersive X-ray spectroscopy (EDX) further validates the persistence of aluminum contamination, limiting the reliability of this method for medical implant post-processing.

Glass Bead Abrasive Blasting offers an alternative to aluminum oxide by reducing contamination from aluminum particulates. With a Mohs hardness 5.5, glass beads are aggressive enough to remove surface inconsistencies while being gentler than aluminum oxide. However, like aluminum oxide, glass beads are prone to fracturing upon impact, leaving microscopic silicon-containing residues embedded within the titanium surface.

Although this technique reduces aluminum-related contamination, it introduces another problem—silicon debris. EDX analysis has shown that silicon residues persist post-treatment, meaning this method does not ensure a pristine, uncontaminated titanium surface. These residual particulates can influence both the implant’s long-term mechanical stability and overall biocompatibility.

The definitive post-processing choice

According to Himed, Apatitic Abrasive Blasting is the apex of post-processing excellence: the company’s proprietary MATRIX MCD technique surpasses conventional post-processing methods in efficacy and safety. This approach employs a calcium phosphate-based abrasive medium composed of hydroxyapatite and tricalcium phosphate, which are naturally found in bone composition. Unlike aluminum oxide and glass bead blasting, apatitic abrasives are wholly soluble and dissolve entirely after ASTM F86 passivation, leaving no foreign contaminants behind.

This method offers unmatched biocompatibility by ensuring no residual particles remain embedded in the titanium surface. The resulting microtopography enhances osseointegration, providing an optimal structure for cellular adhesion and bone ingrowth. Because apatitic abrasives come in various particle sizes, they allow for highly precise refinement of complex implant geometries. Additionally, this process preserves the structural integrity of the implant, maintaining strict dimensional tolerances crucial for mechanical reliability.

Enhance the success of 3D printed medical implants with surface optimization. Discover the benefits of apatitic abrasive blasting via MATRIX MCD  for improved osseointegration.
SEM sequence demonstrating the post-passivation results of a MATRIX MCD application of <53μm apatitic abrasive. Particle size impacts the relative smoothness of the refined surface, with larger MCD of 425–180μm yielding a rougher surface topography. All images are the property of Himed, LLC.

With a Mohs hardness rating of 5, apatitic abrasive blasting delivers a controlled and uniform surface refinement, achieving a surface roughness (Ra) between 1.0μm and 3.2μm, depending on processing parameters. Unlike aluminum oxide and glass bead blasting, this technique ensures absolute titanium purity after passivation, making it the superior choice for post-processing 3D printed titanium implants.

SEM analysis confirms that implants treated with Himed’s MATRIX MCD apatitic abrasive blasting exhibit a fully textured yet contamination-free titanium surface. Unlike other post-processing techniques, this approach removes embedded particulates, ensuring the highest purity level. Decades of refinement have perfected this technique to meet the rigorous quality standards required in orthopedic and dental implant manufacturing.

For medical implants, the composition and texture of the surface directly impact both safety and clinical performance. While aluminum oxide and glass bead blasting introduce foreign residues that can compromise implant integrity, apatitic abrasive blasting provides a biocompatible, residue-free solution. As the field of 3D printed titanium implants continues to advance, selecting the optimal post-processing method remains a critical factor in ensuring their longevity and clinical success.